Product Name: Aeon Labs Smart Strip
Brand Name: Aeon Labs
Product Line:
Product Code:
Product Version: 1
Product Comment:
Battery Type:
Battery Count:
Description: Aeotec by Aeon Labs Smart Strip is a power board with 6 power points of which 4 can be wireless controlled. Customer can turn on/off their electrics when needed with manually operation or Z‐wave wireless control.
Inclusion Note:
Wakeup Note:
 
Default Image: Not available

Device Data

Hash Weak: 04-10-01
Hash Strong: 0086-0003-000b-03-03-43-00-00
Manufacturer: AEON Labs (0x0086)
Product Type ID: 0x0003
Product ID: 0x000B
Library Type: 0x03
Protocol Version: 0x03
Protocol Sub Version: 0x43
Application Version: 0x00
Application Sub Version: 0x00
Basic Class: Slave with routing capabilities
Generic Class: Binary Switch
Specific Class: Binary Power Switch
Optional Flag: Yes
Listening Flag: Yes
Routing Flag: No
Beam Sensor
RF Frequency US
Certification ID:
Certification Number:
Submitter: tolo
Create time: 2015-09-08 13:11:59
Last changed: 2016-02-04 13:09:35

Implemented Command Classes

Command Class Byte Version Support Control In NIF Secure Non Secure
Binary Switch 0x25 1 Yes No Yes No Yes
Meter 0x32 3 Yes No Yes No Yes
All Switch 0x27 1 Yes No Yes No Yes
Basic 0x20 1 Yes No Yes No Yes
Multi Channel 0x60 2 Yes No Yes No Yes
Configuration 0x70 1 Yes No Yes No Yes
Association 0x85 1 Yes No Yes No Yes
Manufacturer Specific 0x72 2 Yes No Yes No Yes
Version 0x86 1 Yes No Yes No Yes
Mark 0xEF 1 Yes No Yes No Yes
Hail 0x82 1 Yes No Yes No Yes

Config Parameters

Paramter No. 4 Size 1 Default 1
Name Wattage Report
Description Enable selective reporting only when power change reaches a certain threshold or percentage set in parameterrs 4‐11.
Type constant
Values
0   ->   disable
1   ->   enable
 
Paramter No. 5 Size 2 Default 25
Name Automatic Report Whole Smart Strip
Description Threshold change in wattage to induce an automatic report.
Type range
Values
0 W - -27233 W   ->   Define a change in wattage to induce a report.
 
Paramter No. 6 Size 2 Default 25
Name Automatic Report Socket 1
Description Threshold change in wattage to induce an automatic report.
Type range
Values
0 W - -27233 W   ->   Define a change in wattage to induce a report.
 
Paramter No. 7 Size 2 Default 25
Name Automatic Report Socket 2
Description Threshold change in wattage to induce an automatic report.
Type range
Values
0 W - -27233 W   ->   Define a change in wattage to induce a report.
 
Paramter No. 8 Size 2 Default 25
Name Automatic Report Socket 3
Description Threshold change in wattage to induce an automatic report.
Type range
Values
0 W - -27233 W   ->   Define a change in wattage to induce a report.
 
Paramter No. 9 Size 2 Default 25
Name Automatic Report Socket 4
Description Threshold change in wattage to induce an automatic report.
Type range
Values
0 W - -27233 W   ->   Define a change in wattage to induce a report.
 
Paramter No. 10 Size 2 Default 25
Name Automatic Report Socket 5
Description Threshold change in wattage to induce an automatic report.
Type range
Values
0 W - -27233 W   ->   Define a change in wattage to induce a report.
 
Paramter No. 11 Size 2 Default 25
Name Automatic Report Socket 6
Description Threshold change in wattage to induce an automatic report.
Type range
Values
0 W - -27233 W   ->   Define a change in wattage to induce a report.
 
Paramter No. 12 Size 1 Default 5
Name Automatic Report Whole Smart Strip
Description Percentage change in wattage to induce an automatic report.
Type range
Values
0 % - 100 %   ->   Define a change in wattage to induce a report.
 
Paramter No. 13 Size 1 Default 5
Name Automatic Report Socket 1
Description Percentage change in wattage to induce an automatic report.
Type range
Values
0 % - 100 %   ->   Define a change in wattage to induce a report.
 
Paramter No. 14 Size 1 Default 5
Name Automatic Report Socket 2
Description Percentage change in wattage to induce an automatic report.
Type range
Values
0 % - 100 %   ->   Define a change in wattage to induce a report.
 
Paramter No. 15 Size 1 Default 5
Name Automatic Report Socket 3
Description Percentage change in wattage to induce an automatic report.
Type range
Values
0 % - 100 %   ->   Define a change in wattage to induce a report.
 
Paramter No. 16 Size 1 Default 5
Name Automatic Report Socket 4
Description Percentage change in wattage to induce an automatic report.
Type range
Values
0 % - 100 %   ->   Define a change in wattage to induce a report.
 
Paramter No. 17 Size 1 Default 5
Name Automatic Report Socket 5
Description Percentage change in wattage to induce an automatic report.
Type range
Values
0 % - 100 %   ->   Define a change in wattage to induce a report.
 
Paramter No. 18 Size 1 Default 5
Name Automatic Report Socket 6
Description Percentage change in wattage to induce an automatic report.
Type range
Values
0 % - 100 %   ->   Define a change in wattage to induce a report.
 
Paramter No. 80 Size 1 Default 0
Name Status of Load
Description Status of load changed,send group 1 associate nodes Hail CC or Basic report CC.
Type constant
Values
0   ->   No send.
1   ->   Send Hail CC.
2   ->   Send Basic report.
 
Paramter No. 90 Size 2 Default
Name Get Temperature
Description Get temperature of Smart Strip(Only GET is valid).
Type bitset
Values
0   ->   2^-8
1   ->   2^-7
2   ->   2^-6
3   ->   2^-5
4   ->   2^-4
5   ->   2^-3
6   ->   2^-2
7   ->   2^-1
8   ->   2^0
9   ->   2^1
10   ->   2^2
11   ->   2^3
12   ->   2^4
13   ->   2^5
14   ->   2^6
15   ->   -(2^7)
 
Paramter No. 100 Size 1 Default
Name Reset Parameters 0x65~0x67
Description Reset 0x65~0x67 to default value
Type constant
Values
 
Paramter No. 101 Size 4 Default 0
Name Auto Report Item 1
Description Configure auto report which information as item 1
Type bitset
Values
0   ->   Auto report the total power consum ption of all channels with specified time interval
1   ->   Auto report power consum ption with specified time interval (channel 1)
2   ->   Auto report power consump tion with specified time interval (channel 2)
3   ->   Auto report power consump tion with specified time interval (channel 3)
4   ->   Auto report power consump tion with specified time interval (channel 4)
5   ->   Auto report power consump tion with specified time interval (channel 5)
6   ->   Auto report power consump tion with specified time interval (channel 6)
7   ->   (Reserved)
8   ->   Auto report the total power level of all channels With specified time interval
9   ->   Auto report power level with specified time interval (channel 1)
10   ->   Auto report power level with specified time interval (channel 2)
11   ->   Auto report power level with specified time interval (channel 3)
12   ->   Auto report power level with specified time interval (channel 4)
13   ->   Auto report power level with specified time interval (channel 5)
14   ->   Auto report power level with specified time interval (channel 6)
15   ->   (Reserved)
16 - 31   ->   (Reserved)
 
Paramter No. 102 Size 4 Default 0
Name Auto Report Item 2
Description Configure auto report which information as item 2, equivalent to parameter 101
Type bitset
Values
0   ->   Auto report the total power consum ption of all channels with specified time interval
1   ->   Auto report power consum ption with specified time interval (channel 1)
2   ->   Auto report power consum ption with specified time interval (channel 2)
3   ->   Auto report power consum ption with specified time interval (channel 3)
4   ->   Auto report power consum ption with specified time interval (channel 4)
5   ->   Auto report power consum ption with specified time interval (channel 5)
6   ->   Auto report power consum ption with specified time interval (channel 6)
7   ->   (Reserved)
8   ->   Auto report the total power level of all channels With specified time interval
9   ->   Auto report power level with specified time interval (channel 1)
10   ->   Auto report power level with specified time interval (channel 2)
11   ->   Auto report power level with specified time interval (channel 3)
12   ->   Auto report power level with specified time interval (channel 4)
13   ->   Auto report power level with specified time interval (channel 5)
14   ->   Auto report power level with specified time interval (channel 6)
15   ->   (Reserved)
16 - 31   ->   (Reserved)
 
Paramter No. 103 Size 4 Default 0
Name Auto Report Item 3
Description Configure auto report which information as item 3, equivalent to parameter 101
Type bitset
Values
0   ->   Auto report the total power consum ption of all channels with specified time interval
1   ->   Auto report power consum ption with specified time interval (channel 1)
2   ->   Auto report power consum ption with specified time interval (channel 2)
3   ->   Auto report power consum ption with specified time interval (channel 3)
4   ->   Auto report power consum ption with specified time interval (channel 4)
5   ->   Auto report power consum ption with specified time interval (channel 5)
6   ->   Auto report power consum ption with specified time interval (channel 6)
7   ->   (Reserved)
8   ->   Auto report the total power level of all channels With specified time interval
9   ->   Auto report power level with specified time interval (channel 1)
10   ->   Auto report power level with specified time interval (channel 2)
11   ->   Auto report power level with specified time interval (channel 3)
12   ->   Auto report power level with specified time interval (channel 4)
13   ->   Auto report power level with specified time interval (channel 5)
14   ->   Auto report power level with specified time interval (channel 6)
15   ->   (Reserved)
16 - 31   ->   (Reserved)
 
Paramter No. 110 Size 1 Default
Name Reset Parameters 0x6F~0x71
Description Reset parameter 0x6F~0x71 to factory default
Type constant
Values
 
Paramter No. 111 Size 4 Default 600
Name Auto Report Time Interval Item 1
Description Configure auto report time interval of item 1
Type range
Values
 
Paramter No. 112 Size 4 Default 600
Name Auto Report Time Interval Item 2
Description Configure auto report time interval of item 2
Type range
Values
 
Paramter No. 113 Size 4 Default 600
Name Auto Report Time Interval Item 3
Description Configure auto report time interval of item 3
Type range
Values
 
Paramter No. 252 Size 1 Default 0
Name Lock Parameter
Description
Type constant
Values
0   ->   unlock
1   ->   Lock
 
Paramter No. 253 Size 4 Default
Name Enter Meter Calibration Mode
Description
Type constant
Values
 
Paramter No. 254 Size 2 Default 0
Name Device Tag
Description Device tag,inclusion and/or reset will not change the value.
Type constant
Values
 
Paramter No. 255 Size 1 Default
Name Restore All
Description Restore Configuration parameters to factory default, except parameter 254.
Type constant
Values
 

Association Groups

Group Number Max Nodes Description
1 5 Hail Command, Basic Report

Endpoints

Alarm Mappings

 