Product Name: Roller Shutter FGRM-222
Brand Name: Fibargroup
Product Line:
Product Code: FGRM-222
Product Version:
Product Comment: Roller Shutter 2
Battery Type:
Battery Count:
Description: Very thin and little wall insert blind control to be mounted behind a standard switch
Inclusion Note: Tripple Press little button on device
Wakeup Note:
 
Default Image: Not available

Device Data

Hash Weak: 04-11-06
Hash Strong: 010f-0301-1001-03-03-34-16-16
Manufacturer: Fibargroup (0x010F)
Product Type ID: 0x0301
Product ID: 0x1001
Library Type: 0x03
Protocol Version: 0x03
Protocol Sub Version: 0x34
Application Version: 0x16
Application Sub Version: 0x16
Basic Class: Slave with routing capabilities
Generic Class: Multilevel Switch
Specific Class: Motor Control Class B
Optional Flag: Yes
Listening Flag: Yes
Routing Flag: Yes
Beam Sensor 0
RF Frequency
Certification ID:
Certification Number:
Submitter: cpae
Create time: 2013-11-28 10:04:54
Last changed: 2014-11-05 12:23:58

Implemented Command Classes

Command Class Byte Version Support Control In NIF Secure Non Secure
Basic 0x20 1 Yes No No No Yes
Association 0x85 2 Yes No Yes No Yes
Version 0x86 1 Yes No Yes No Yes
Multilevel Sensor 0x31 2 Yes No Yes No Yes
Manufacturer Specific 0x72 1 Yes No Yes No Yes
Configuration 0x70 1 Yes No Yes No Yes
Manufacturer Proprietary 0x91 1 Yes No Yes No Yes
Meter 0x32 2 Yes No Yes No Yes
Powerlevel 0x73 1 Yes No Yes No Yes
Protection 0x75 2 Yes No Yes No Yes
Firmware Update Meta Data 0x7A 1 Yes No Yes No Yes
Binary Switch 0x25 1 Yes No Yes No Yes

Config Parameters

Paramter No. 1 Size 1 Default 0
Name local protection
Description enables/disables local entry. If activated module stops responding to S1 and S2 push buttons, SCENE ID and association commands will not be sent. Only exception is the B-button.
Type rangemapped
Values
0   ->   0 - no protection. Roller Shutter responds to push buttons.
1   ->   1 - not supported.
2   ->   2 - Local protection active. Roller Shutter does not respond to push buttons.
 
Paramter No. 2 Size 1 Default 0
Name radio protection
Description enables/disables RF protection. If activated device stops responding to command frames. Configuration and polling still possible.
Type rangemapped
Values
0   ->   0 – No protection. Roller Shutter responds to command frames.
1   ->   1 - RF Protection active. Roller Shutter does not respond to the Z-Wave control frames.
2   ->   2 - not supported.
 
Paramter No. 3 Size 1 Default 0
Name reports type
Description Parameters value shoud be set to 1 if the module operates in Venetian Blind mode.
Type rangemapped
Values
0   ->   0 – Blind position reports sent to the main controller using Z-Wave Command Class.
1   ->   1 - Blind position reports sent to the main controller using Fibar Command Class.
 
Paramter No. 10 Size 1 Default 1
Name Roller Shutter operating modes
Description parameter sets the operating mode.
Type rangemapped
Values
0   ->   0 - Roller Blind Mode, without positioning
1   ->   1 - Roller Blind Mode, with positioning
2   ->   2 - Venetian Blind Mode, with positioning
3   ->   3 - Gate Mode, without positioning
4   ->   4 - Gate Mode, with positioning
 
Paramter No. 12 Size 2 Default 150
Name turning time/ delay time
Description In Venetian Blind mode (parameter 10 set to 2) the parameter determines time of full turn of the lamellas. In Gate Mode (parameter 10 set to 3 or 4) the parameter defines the delay time after which an open gate starts closing.
Type range
Values
-32767 0,01s - 32767 0,01s   ->   Value 0 means the gate will not close automatically.
 
Paramter No. 13 Size 1 Default 1
Name lamellas positioning mode
Description parameter influences the lamellas positioning in venetian blind mode (parameter 10 set to 2)
Type rangemapped
Values
0   ->   0 - Lamellas return to previously set position only in case of the main controller operation.
1   ->   1 - Lamellas return to previously set position in case of the main controller operation, momentary switch operation, or when the limit switch is reached.
2   ->   2 - Lamellas return to previously set position in case of the main controller operation, momentary switch operation, when the limit switch is reached or after receiving a “STOP” control frame (Switch Multilevel Stop).
 
Paramter No. 14 Size 1 Default 0
Name switch type
Description parameter settings are relevant for Roller Blind Mode and Venetian Blind Mode (parameter 10 set to 0, 1, 2).
Type rangemapped
Values
0   ->   0 - Momentary switches
1   ->   1 - Toggle switches
2   ->   2 - Single, momentary switch. (The switch should be connected to S1 terminal)
 
Paramter No. 17 Size 1 Default 10
Name delay time after S2
Description In roller blind mode or venetian blind mode (parameter 10 set to 0, 1, 2) the parameter determines when the Roller Shutter relays are turned off after reaching a limit switch. In Gate Mode (parameter 10 set to 3 or 4) the parameter determines a time period after which a gate will start closing after a S2 contact has been disconnected.
Type range
Values
-127 0,1s - 127 0,1s   ->   value 10 = 1s. In Gate Mode, time to turn off the Roller Shutter relays after reaching a limit switch is set to 3 seconds and cannot be modified. Value of 0 means the gate will note close automatically.
 
Paramter No. 18 Size 1 Default 10
Name motor operation detection
Description Power threshold to be interpreted as reaching a limit switch.
Type range
Values
-127 1W - 127 1W   ->   The value of 0 means reaching a limit switch will not be detected.
 
Paramter No. 22 Size 2 Default 240
Name motor operation time
Description Time period for the motor to continue operation.
Type range
Values
-32767 1s - 32767 1s   ->   value of 0 means the function is disabled.
 
Paramter No. 29 Size 1 Default 0
Name Forced Roller Shutter calibration
Description seting the parameter to 1 Roller Shutter enters the calibration mode. Parameteronly is only relevant if a Roller Shutter is set to work in positioning mode (parameter 10 set to 1, 2 or 4).
Type rangemapped
Values
0   ->   0 - deactivated (value 0 is automatically set after calibration process)
1   ->   1 - Start calibration process
 
Paramter No. 30 Size 1 Default 2
Name Response to general alarm
Description
Type rangemapped
Values
0   ->   0 - No reaction.
1   ->   1 - Open blind.
2   ->   2 - Close blind.
 
Paramter No. 31 Size 1 Default 0
Name Response to flooding alarm
Description
Type rangemapped
Values
0   ->   0 - No reaction.
1   ->   1 - Open blind.
2   ->   2 - Close blind.
 
Paramter No. 32 Size 1 Default 1
Name Response to smoke, CO or CO2 alarm
Description
Type rangemapped
Values
0   ->   0 - No reaction.
1   ->   1 - Open blind.
2   ->   2 - Close blind.
 
Paramter No. 33 Size 1 Default 1
Name Response to temperature alarm
Description
Type rangemapped
Values
0   ->   0 - No reaction.
1   ->   1 - Open blind.
2   ->   2 - Close blind.
 
Paramter No. 35 Size 1 Default 1
Name Managing lamellas in response to alarm
Description In Venetian Blind Mode (parameter 10 set to 2), the parameter determines how the lamellas will react upon alarm detection.
Type rangemapped
Values
0   ->   0 - Do not change lamellas position - lamellas return to the last set position.
1   ->   1 - Set lamellas to their extreme position.
 
Paramter No. 40 Size 1 Default 10
Name Power reports
Description Power level change that will result in new power value report being sent. value is a percentage of the previous report.
Type range
Values
1 1% - 100 1%   ->   Value of 0 means the reports are turned off.
 
Paramter No. 42 Size 2 Default 3600
Name Periodic power or energy reports
Description time to the next report
Type range
Values
-32767 1s - 32767 1s   ->   Value of 0 means the reports are turned off.
 
Paramter No. 43 Size 1 Default 10
Name Energy reports
Description Energy level change which will result in new energy value report being sent.
Type range
Values
-126 0,01KWh - 127 0,01KWh   ->   Value of 0 means the reports are turned off.
 
Paramter No. 44 Size 1 Default 0
Name Self-measurement
Description enables/disables to include the power and energy used by itself in reports to main controller.
Type rangemapped
Values
0   ->   0 - Self-measurement inactive.
1   ->   1 - Self-measurement active.
 
Paramter No. 50 Size 1 Default 0
Name Scenes/ Associations activation
Description Parameter determines whether scenes or associations are activated by the switch keys.
Type rangemapped
Values
0   ->   0 - Associations activation
1   ->   1 - Scenes activation
 

Association Groups

Group Number Max Nodes Description
3 1 reports the module status; default setting primary controller
2 16 triggered through a momentary switch hold
1 16 triggered through a momentary switch click or a toggle switch position change

Endpoints

Alarm Mappings

 

Back to list, XML